Click to enlarge image
|
|

|
| Traction Type
Demensions of Hoistway M/C Room Section (unit : mm)
Speed Overhead Pit Depth M/C Room
(m/min) (O.H) (P) Height(M.H)
30,45 4450 1250 2500
60 4650 1550
Standard Dimensions
Speed Type Clear Car Internal Shaft Internal Machine Room M/C Room Impact Load
(m/min) Opening Demension Dimension Internal Reaction on the Pit
(MAX) (mm) (mm) Dimension (kg) (kg)
(mm) (mm)
X X Y MA X MB
W X H A X B R1 R2 Car side Cwt side
(p1) (P2)
30 C2000-2U,3U 2350X 2350X 3500X 5500X 13500 / 14400 9000 / 15500/ 12600/
45 1800 5250 6000 6000 9600 21100 17300
60 C2500-2U,3U 2750X 2750X 3900X 5900X 16400 / 17500 10800/ 19500/ 15700/
1800 6150 6900 6900 11700 25500 20500
※ Notes 1. It is required to install the ventilation fan and grille in machine room
considering of heat generation and maintenance conveniences.
2. As the hoistway inside dimensions shown on the table are the minimum size,
some allowance are required considering the slope of the hoistways.
3. It is also required any prior confirmation in the event of using the forklift.
(Any technical information of forklift in use at your company is required)
4. The calculating formula(mm) of Minimum floor Height.
?2u → H x 1.5 + 600 <= Minimum floor Height
?3u → H x 4/3 + 600 <= Minimum floor Height
∴ H : The height of the entrancle door
5. The internal car size of two-way entrance car type should be confirmed us
as it is quite different from the standard dimension of the hoistway.
Indirect Roped Plunger Type
Dimensions of Hoistway and M/C Room Section (unit : mm)
Overhead Pit Depth M/C Room Travel(T.R)
(m/min) (P) Height(M.H) (MAX)
4100 1250 2100 20000
Dimensions of Hoistway and M/C Room
Speed Type Capacity Clear Car Internal Shaft Internal Machine Room Internal Impact Load on the Pit(kg)
(m/min) (kg) Opening(MAX) Demension Dimension(mm) Dimension(mm)
(mm) (mm) X X Y MA X MB
W X H A X B Car side(p1) Cylinder side(P2)
15 HIC2000-2U,3U 2000 2350 X 1800 2350 x 5250 3600 X 6000 2350 x 4500 9000 8100
20 HIC2500-2U,3U 2500 2750 X 1800 2750 x 6150 4000 X 6900 2300 x 4500 10500 9900
※ Notes 1. It is desirable that the machine room is locating at the lowest floor within 10
meters from the sides of the hoistway.
2. The calculating formula(mm) of Minimum floor Height.
?2u → H x 1.5 +600 <= Minimum floor Height
?3u → H x 4/3 + 600 <= Minimum floor Height
∴ H : The height of the entrancle door
3. It is required to install the ventilation fan and grille in machine room
considering of heat generation and maintenance conveniences.
4. It is also required any prior confirmation in the event of using the forklift.
(Any technical information of forklift in use at your company is required)
5. The internal car size of two-way entrance car type should be confirmed us
as it is quite different from the standard dimension of the hoistway.
|
|
| |
|
|
|